The Plastic Scintillators detectors are part of the timing system of the Super-FRS. They will be used to provide the timing signals of the travelling ion beams. Being fast enough to allow for triggering, they will be used for performing in-beam (time) calibration of other Super-FRS detectors. Additionally, FMF2 and …
Cold Terminals are parts of the current leads for superconducting corrector magnets for SIS100 synchrotron. They provide a good electrical insulation from the ground and a good thermal contact to the heat sink at ground level. The cold terminals are rated at 250 A DC and consist of copper parts …
Zyklotron Zyklotron inkl. Arbeits- und Dienstleistungen
Predmet nabave je sklop elektrostatske leće (Q-snout) za bolju transmisiju ionskog snopa u 5.0 MV Tandetron akceleratoru proizvođača High Voltage Engineering Europa Predmet nabave je sklop elektrostatske leće (Q-snout) za bolju transmisiju ionskog snopa u 5.0 MV Tandetron akceleratoru proizvođača High Voltage Engineering Europa
Für das geplante bevorstehende Vergabeverfahren zum Projekt Zyklotron und Heiße Zellen wird vorab eine Markterkundung durchgeführt. Der Ablauf der Markterkundung erfolgt zweistufig. Ziel der Markterkundung ist es, die technischen Eigenschaften, Einsatzmöglichkeiten und Alleinstellungsmerkmale nachvollziehbar darzustellen und eine fundierte Vergleichbarkeit mit anderen Lösungen zu ermöglichen. Für das geplante bevorstehende Vergabeverfahren zum …
ENNAKKOILMOITUKSEN TAUSTA JA TARKOITUS Tuomi Logistiikka Oy (jäljempänä "Hankintayksikkö") valmistelee Pirkanmaan hyvinvointialueen (jäljempänä ”Pirha” tai ”tilaaja”) toimeksiannosta tarjouskilpailua hiukkaskiihdytinlaboratorion laitteistokokonaisuuden hankkimiseksi. Hankintayksikkö kokoaa tietoa markkinatoimijoista ja heidän tarjoamistaan ratkaisuista ja julkaisee tätä tarkoitusta varten nyt ennakkoilmoituksen / tietopyynnön (jäljempänä ”Ennakkoilmoitus”). Ennakkoilmoitus ei ole hankintailmoitus tai tarjouspyyntö vaan kutsu markkinavuoropuheluun ja …
Solenoid and dipole magnets for the IMPACT project at the HIPA facility at Paul Scherrer Institute, Switzerland. For details see the Requirements Specification PSI-HIPA-SS84-014 Rev. 1.0. Solenoid- und Dipolmagnete für das IMPACT-Projekt der HIPA-Anlage am Paul Scherrer Institut, Schweiz. Einzelheiten siehe Anforderungsspezifikation PSI-HIPA-SS84-014 Rev. 1.0. Aimants solénoïdes et dipôles pour …
Scopul acestei proceduri de atribuire este achiziția unor componente pentru imbunatatirea intensitatii fasciculului de electroni pentru LINAC-ul ELI-NP existent impreuna cu serviciile de proiectare ale acestora, conform Caietului de sarcini, asigurând astfel realizarea obiectivelor de intensitate a fasciculului gamma al proiectului. În temeiul prevederilor art. 160 din Legea nr. 98/2016, …
Für das geplante bevorstehende Vergabeverfahren zum Projekt Zyklotron und Heiße Zellen wird vorab eine Markterkundung durchgeführt. Der Ablauf der Markterkundung erfolgt zweistufig. Ziel der Markterkundung ist es, die technischen Eigenschaften, Einsatzmöglichkeiten und Alleinstellungsmerkmale nachvollziehbar darzustellen und eine fundierte Vergleichbarkeit mit anderen Lösungen zu ermöglichen. Für das geplante bevorstehende Vergabeverfahren zum …
Le présent marché concerne la réalisation de 4 cavités accélératrices supraconductrices elliptiques 5 celulles ; dénommées « cavité/réservoir ». Une « cavité/réservoir » est un ensemble qui comprend une cavité, composée en majorité de niobium et son réservoir d'hélium, composé en majorité de titane. Le CNRS fournit tout le niobium …